UNDEREAVE VENT
The undereave vent is an intake vent that allows air to enter the attic. As an essential component of a ridge vent system, the undereave vent provides the other half of the air movement equation by creating a balanced attic.
According to most building codes, you need 1 square foot of ventilation for every 150 square feet of attic floor space. For new home construction that includes a vapor retarder, the minimum is 1 square foot of ventilation for every 300 square feet of attic floor space. If your vents are split between ridge vents and intake vents, the minimum requirement is also 1 square foot of ventilation for every 300 square feet of attic floor space.
- 8-mesh aluminum screen
- 16" x 8", 12 gauge
- Galvanized, mill finish, can be painted
- Provides 56 sq. in. of net free air